DC70S – Specification
Rated power 70 kW | ||
Boiler efficiency 86,3 % | ||
Emission class nr. 4 | ||
Log lenght 730 mm |
Description of the boiler drawing | |||
---|---|---|---|
1. | Boiler body | 22. | Door filling – Sibral |
2. | Filling door – upper | 23. | Door sealing – cord 18 x 18 |
3. | Ashtray door – lower | 25. | Capacitator for exhaust fan |
4. | Ventilator – pressure | 26. | Heatproof shaped piece – half moon |
5. | Heatproof shaped piece – nozzle | 27. | Heatproof shaped piece – combustion area plate |
6. | Control panel | 28. | Flue gas brake for rear flue way duct |
7. | Regulating flap | 29. | Cleaning aperture |
10. | Nozzle sealing – 12×12 (14×14) | 30. | Waste gas thermostat |
12. | Ignition valve | 31. | Safety thermostat (Caution – in overheat condition must be depressed) |
14. | Cleaning lid – upper and lower | 34. | Primary air regulation |
15. | Ignition valve pulling rod | 35. | Secondary air regulation |
16. | Thermometer | ||
17. | Frame shield | K | – flue gas duct neck |
18. | Switch with an indicator light | L | – water outlet from |
19. | Draught regulator – Honeywell FR 124 | M | – boiler – water inlet to |
20. | Cooling loop protecting against overheating | N | – boiler – filling valve |
21. | Ventilator control thermostat (boiler) | P | – pipe sleeve – sleeve for cooling loop control valve sensor (TS 131, STS 20) |
Boiler type | DC70S | |
Boiler heat output | kW | 70 |
Boiler thermal input | kW | 79,9 |
Heating surface | m2 | 5 |
Fuel shaft volume | dm3 (l) | 180 |
Feeding hole dimensions | mm | 450 x 260 |
Prescripted chimney draft | Pa / mbar | 30 / 0,30 |
Max. operating water-pressure | kPa / bar | 250 / 2,5 |
Boiler weight | kg | 515 |
Gas-outlet pipe diameter | mm | 180 |
Electric parts ingress protection | IP | 20 |
Electrical power input (auxiliary) | W | 50 |
Electrical input in standby mode | W | 0 (3/5,5) |
Ignition mode |
manual | |
Boiler efficiency | % | 86,3 |
Boiler class | 4 | |
Boiler category | 1 | |
Operating mode | non-condensing | |
Solid fuel boiler with cogeneration unit | no | |
Combined device also for heating of DHW | no | |
Energy efficiency class | A+ | |
Waste gas temperature at nominal output as per EN 303-5 | °C | 220,3 |
Flue gas temperature / draught for calculating the flue gas path (chimney) |
°C / Pa | 240 / 30 |
Waste gas combustion products flow weight at nominal output | kg / s | 0,035 |
Specified fuel (preffered) | dry wood (logs) of 15 – 17 MJ.kg-1 caloric power, min. 12 – 20 % max. water content and 80 – 150 mm diameter. | |
Average fuel consumption | kg.h-1 | 18 |
Fuel consumption per heating season | 1 kW = 1 m3 | |
Prescribed wood length | mm | 730 |
Combustion time at nominal output | hours | 2 |
Boiler water volume | l | 93 |
Hydraulic pressure drop | mbar | 0,25 |
Equalising tank minimum volume | l | 1000 |
Connecting voltage | V / Hz | 230 / 50 |
EKODESIGN |
yes |
Dimensions (mm) | DC70S |
A | 1399 |
B | 1166 |
C | 678 |
D | 1047 |
E | 180 |
F | 90 |
G | 325 |
H | 423 |
CH | 0 |
I | 240 |
J | 2″ |